We would like to introduce the HV1600-2 Speed.  The Unit has two speed settings, low/high.  On low the unit performs like an HV1000 with 900 cfm of air flow.  On high the unit does 1600 cfm of air flow.

Unlike other systems, the HV series requires no maintenance.  The fan motors of the HV1600 are of extremely high quality and are built to last.  The unit is available as a standard with R-22 insulated doors.  There is an option for R-38 insulation.  The HV series of fans are insulated and when not in use form an air tight seal between your attic and living space.    There is no other unit available that boasts these levels of insulation and protection.  As an additional quality control method, every single unit is tested and run at the factory for 24 hours prior to shipping, a commitment to a great product which we can say is Made In The Usa.
 
House Size: HV1600 Typical  24" Fan Typical 30" Fan
Air Flow: 900 cfm/low 3000 cfm 6000 cfm
  1600 cfm/high    
1500 Square Ft.: 7.5 minutes/high 4 minutes 2 minutes
2000 Square Ft.: 10 minutes/high 5.33 minutes 2.67 minutes
2500 Square Ft.: 12.5 minutes/high 6.67 minutes 3.33 minutes

For 2006 The HV1600 is available in the following models:

HV1600-GR:
 2 Speed, R-22 insulation w/Remote.
HV1600-GDR: 2 Speed, R-38 insulation w/Remote.
 
Tamarack HV1600 whole house fan closed
HV1600-GR Closed
(click image to enlarge)
Tamarack HV1600-GDR whole house fan closed
HV1600-GDR Closed
(click image to enlarge)
Tamarack HV1600-GDR whole house fan opened
HV1600-GR Opened
(click image to enlarge)
Tamarack HV1600-GDR whole house fan opened with R38 insulation
HV1600-GDR Opened
(click image to enlarge)

Typical Sizing Chart: Whole House Fan Sizing Chart

Specifications:

Power Requirements: 115V AC 60 HZ
Fans Running: 276 Watts
Lift Motors Running: 6 Watts
Open/Close Time: 30 Seconds
Air Flow @ .1 SP: 900 cfm low/1600 cfm high.
Sound Level: TBA
R Value Closed Panel: R-22
Rough Opening: 14.5" x 22.5"
Height With Door Open: 11" @ R-22, 12" @ R-38
Interior Grille: Return Air white
Approx. Amps: 1.02 Low/2.4 High
Weight: 27 lbs (35 lbs shipped)
Net Free Area Required: 3 Square Feet

Grille: The HV system includes a 24" x 14" white return air grille.  The outside diameter of the grille measures 25 3/4" x 15 3/4".  The rough opening of the grille measures 23 1/4" x 13 7/8". 

Controls
: The units come standard with RF remote controls, which have a range of approximately 30'.  The units can also be hard wired to a wall switch.  Both controls together can also be used.  However, on/off and speed functions if turned on with the remote must be used with the remote and vice versa with the wall switch for the duration the fan is running.
 

Wireless Remote Control (RC) for the HV1600:  The wireless remote control is a very popular item as there is no need to run electrical line down a wall for the switch, although if desired once can also be used with this unit.
 

The dedicated remote control system offers the user a simplified 110 volt powered remote control.  The system includes a hand-held transmitter, which operates on a 12-volt battery (included),  a receiver which has been built into the fan. The transmitter features a signal operating light that goes on when the ON or OFF buttons are depressed. The controls offer 256 unique security codes that are factory programmed into the system allowing multiple remote control units in the same room or building. The systems operating distance is 60' and is not restricted to "line-of-sight" applications because the system uses radio frequency control. It operates on the R.F. frequency of 303.875 MHz. The control is UL listed and is FCC certified in the U.S. and I.S.C. certified in Canada.

Net Free Area Defined:  For every 750 cfm of airflow, it is recommended that there be a minimum of 1 sq. ft. of attic venting, i.e. roof vents, gable vents, soffit vents, ridge vent.  This will allow the air flow of the fan's exhaust air into the attic the ability to flow out of the home freely. 

To calculate your net free area: - Count and add up your total number of vents in feet.  If your vent(s) are screened take approx. 1/2 away from your total.  For example:

You have four 1 sq. ft  vents, and they are screened.  You would have a 4 sq ft gross of venting, however since the screens will block air flow, you would need to subtract approximately 2 sq. ft of venting from your gross, giving you a 2 sq. ft net free area.

Warranty: The unit comes standard with a 3 year limited warranty.

Wiring The HV1600 as of 12/26/2005:

All HV1600 models are now being shipped with line cords.  A standard household 120 VAC outlet is required, within 6' of the unit.  Once the framed in area has been prepared, Simply plug the fan in and its ready to start cooling.  Download HV1600 Manual Add-on (requires pdf reader)

Wiring The HV1600 Gold 2005/previous models:

The HV1600 Gold requires a constant source of power.  Because the doors are motorized, they need power to open and power to close.  (Fan ON/OFF operation is controlled internally.)  There are four wires in the electrical box: WHITE, BLACK, a YELLOW and a BLUE.

The WHITE should be connected Line Neutral, 115 VAC 60 Hz
The BLACK should be connected to Line Hot, 115 VAC 60 Hz
Connect ground wire to screw in electrical box.

With just the BLACK and WHITE wires connected to power, the HV1600 Gold will be fully functional with the hand held remote control unit.  The YELLOW and BLUE wires can be used to provide "hard wired" control.  The BLUE wire will provide ON/OFF control and the YELLOW wire can provide HIGH or LOW speed control with two separate switches, one for each function.

Note that both sets of buttons on the remote control are marked ON/OFF.  The top pair will activate and deactivate the fan.  The bottom pair turn the HIGH speed on or off.  If the HV 1600 Gold R has been "hard wired" to a wall mounted ON/OFF switch or HIGH/LOW switch or both, note that both the wall switch and the remote control switch cannot be used at the same time. 

  • If the wall mounted ON/OFF switch is in the ON position, the ON/OFF buttons on the remote control will NOT function.

  • If the wall mounted HIGH/LOW switch is set to HIGH, the HIGH/LOW buttons on the remote control will not function

  • Note that when any of the buttons on the remote control are pushed, the Red indicator light should momentarily flash.  If it doesn't and the system fails to operate, first check that the optional "hard wired" wall switches are set to the OFF position and then change the battery in the handheld remote control device.

Order The HV1600

 